Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rev Port Cardiol ; 41(12): 1011-1021, 2022 12.
Article in English, Portuguese | MEDLINE | ID: mdl-36511271

ABSTRACT

INTRODUCTION AND OBJECTIVES: Although automatic artificial intelligence (AI) coronary angiography (CAG) segmentation is arguably the first step toward future clinical application, it is underexplored. We aimed to (1) develop AI models for CAG segmentation and (2) assess the results using similarity scores and a set of criteria defined by expert physicians. METHODS: Patients undergoing CAG were randomly selected in a retrospective study at a single center. Per incidence, an ideal frame was segmented, forming a baseline human dataset (BH), used for training a baseline AI model (BAI). Enhanced human segmentation (EH) was created by combining the best of both. An enhanced AI model (EAI) was trained using the EH. Results were assessed by experts using 11 weighted criteria, combined into a Global Segmentation Score (GSS: 0-100 points). Generalized Dice Score (GDS) and Dice Similarity Coefficient (DSC) were also used for AI models assessment. RESULTS: 1664 processed images were generated. GSS for BH, EH, BAI and EAI were 96.9+/-5.7; 98.9+/-3.1; 86.1+/-10.1 and 90+/-7.6, respectively (95% confidence interval, p<0.001 for both paired and global differences). The GDS for the BAI and EAI was 0.9234±0.0361 and 0.9348±0.0284, respectively. The DSC for the coronary tree was 0.8904±0.0464 and 0.9134±0.0410 for the BAI and EAI, respectively. The EAI outperformed the BAI in all coronary segmentation tasks, but performed less well in some catheter segmentation tasks. CONCLUSIONS: We successfully developed AI models capable of CAG segmentation, with good performance as assessed by all scores.


Subject(s)
Deep Learning , Humans , Tomography, X-Ray Computed , Artificial Intelligence , Retrospective Studies , X-Rays , Coronary Angiography
2.
Rev Port Cardiol (Engl Ed) ; 37(6): 511-520, 2018 Jun.
Article in English, Portuguese | MEDLINE | ID: mdl-29803651

ABSTRACT

INTRODUCTION AND OBJECTIVE: Assessment of coronary lesions by the instantaneous wave free ratio (iFR) has generated significant debate. We aimed to assess the diagnostic performance of iFR and its impact on the decision to use fractional flow reserve (FFR) and on procedural characteristics. METHODS: In this single-center registry of patients undergoing functional assessment of coronary lesions, FFR was used as a reference for assessing the diagnostic performance of iFR. An iFR value <0.86 was considered positive and a value >0.93 was considered negative. RESULTS: Functional testing was undertaken of 402 lesions, of which 154 were assessed with both techniques, 222 with FFR only, and 26 with iFR only. Using a cut-off of ≤0.80 for iFR, the area under the curve was 0.73 (95% CI 0.65-0.81), with an optimal value of ≤0.91. FFR was undertaken in 93 out of 94 lesions with an inconclusive iFR and was performed in 69.1% of the remaining iFR-tested lesions. Concordance between iFR and FFR was 87% (chi-square=22.43; p<0.001). Notwithstanding, there were four out of 13 cases (30.7%) of positive iFR with negative FFR and three out of 42 (7.1%) cases of negative iFR and positive FFR. This difference was significant (p=0.026). iFR had no impact on procedure time, fluoroscopy time or radiation dose. CONCLUSION: iFR had a reasonable diagnostic performance. Operators often chose to perform FFR despite conclusive iFR results. iFR and FFR were highly concordant, but a non-negligible proportion of lesions classified as ischemic by iFR were classified as non-ischemic by FFR. iFR had no impact on procedural characteristics.


Subject(s)
Coronary Stenosis/diagnosis , Coronary Stenosis/physiopathology , Fractional Flow Reserve, Myocardial , Heart Function Tests/methods , Aged , Female , Humans , Male , Registries , Retrospective Studies , Time Factors
3.
Cardiovasc Toxicol ; 18(5): 431-435, 2018 10.
Article in English | MEDLINE | ID: mdl-29616409

ABSTRACT

Chemotherapy-induced cardiotoxicity is a growing concern. The cardiotoxic impact of new drugs such as tyrosine kinase inhibitors is unknown, especially the ones used for chronic myeloid leukemia. We aim to evaluate nilotinib- and imatinib-induced cardiotoxicity. Single-center prospective study of consecutive patients with chronic myeloid leukemia treated with tyrosine kinase inhibitors was conducted during 2015. Patients underwent an initial clinical, laboratorial and echocardiographic evaluation, repeated after 1 year. Eleven patients were included [60.0 (11) years, 63.6% of males; seven patients treated with imatinib and four with nilotinib]. After 1 year of follow-up, all patients remained in functional NYHA class I, with a similar Minnesota quality of life score. Also there was no difference in the biomarkers evaluated (cystatin-C and NT-proBNP). Likewise, no modification in systolic or diastolic function evaluated by echocardiography was observed. All patients presented normal values of longitudinal, circumferential and radial strain in the baseline study, without changes during follow-up. In addition, there were no differences between the two tyrosine kinase inhibitors used, considering all the aforementioned variables. No clinical, laboratory or echocardiographic evidence of nilotinib- and imatinib-induced cardiotoxicity was observed. However, these results should be confirmed in multicenter studies given the low incidence of chronic myeloid leukemia.


Subject(s)
Antineoplastic Agents/adverse effects , Heart Diseases/chemically induced , Imatinib Mesylate/adverse effects , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/drug therapy , Protein Kinase Inhibitors/adverse effects , Pyrimidines/adverse effects , Aged , Cardiotoxicity , Echocardiography , Female , Heart Diseases/diagnostic imaging , Humans , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/enzymology , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/pathology , Male , Middle Aged , Pilot Projects , Portugal , Prospective Studies , Risk Assessment , Time Factors , Treatment Outcome
5.
Vasc Endovascular Surg ; 52(5): 361-366, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29519203

ABSTRACT

Several types of intravascular devices and catheters are frequently used for long-term drug therapy, especially for oncological patients. As a result, complications are becoming increasingly common, namely catheter embolization. Retrieving these devices is important, as embolized fragments may lead to serious consequences, such as arrhythmias, myocardial injury, thrombosis, infection, and even perforation and death. We describe 2 cases of long-term drug catheter (Port-A-Cath) fracture, incidentally documented in a routine chest radiograph. In both cases, percutaneous extraction was attempted, yet the procedure was complicated by embolization of smaller fragments into the arterial pulmonary vasculature. We describe unusual approaches in successfully retrieving the remaining fragments. The ideal approaches for removal of foreign bodies from the cardiovascular system differ from case to case, but percutaneous extraction should be preferred in most of the cases. Less common techniques may be helpful in challenging cases.


Subject(s)
Antineoplastic Agents/administration & dosage , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Device Removal/methods , Embolism/therapy , Foreign-Body Migration/therapy , Pulmonary Artery , Vascular Access Devices/adverse effects , Administration, Intravenous , Embolism/diagnostic imaging , Embolism/etiology , Equipment Design , Female , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humans , Incidental Findings , Middle Aged , Pulmonary Artery/diagnostic imaging , Treatment Outcome
6.
Rev Port Cardiol ; 36(9): 669.e1-669.e4, 2017 Sep.
Article in English, Portuguese | MEDLINE | ID: mdl-28874324

ABSTRACT

The lamin A/C (LMNA) gene encodes lamins A and C, which have an important role in nuclear cohesion and chromatin organization. Mutations in this gene usually lead to the so-called laminopathies, the primary cardiac manifestations of which are dilated cardiomyopathy and intracardiac conduction defects. Some mutations, associated with lipodystrophy but not cardiomyopathy, have been linked to metabolic abnormalities such as diabetes and severe dyslipidemia. Herein we describe a new phenotype associated with a mutation in exon 11 of the LMNA gene: hypertrophic cardiomyopathy, atrioventricular block, severe dyslipidemia and diabetes. A 64-year-old woman with hypertrophic cardiomyopathy and a point mutation in exon 11 of the LMNA gene (c.1718C>T, Ser573Leu) presented with severe symptomatic ventricular hypertrophy and left ventricular outflow tract obstruction. She underwent septal alcohol ablation, followed by Morrow myectomy. The patient was also diagnosed with severe dyslipidemia, diabetes and obesity, and fulfilled diagnostic criteria for metabolic syndrome. No other characteristics of LMNA mutation-related phenotypes were identified. The development of type III atrioventricular block with no apparent cause, and mildly depressed systolic function, prompted referral for cardiac resynchronization therapy. In conclusion, the association between LMNA mutations and different phenotypes is complex and not fully understood, and can present with a broad spectrum of severity.


Subject(s)
Atrioventricular Block/genetics , Cardiomyopathy, Hypertrophic/genetics , Diabetes Complications/genetics , Diabetes Mellitus/genetics , Dyslipidemias/genetics , Lamin Type A/genetics , Mutation , Atrioventricular Block/complications , Cardiomyopathy, Hypertrophic/complications , Dyslipidemias/complications , Exons/genetics , Female , Humans , Middle Aged , Phenotype , Severity of Illness Index
7.
Rev Port Cardiol ; 36(7-8): 525-532, 2017.
Article in English, Portuguese | MEDLINE | ID: mdl-28673783

ABSTRACT

INTRODUCTION: Patients referred for percutaneous transcatheter mitral valve repair using the MitraClip® system frequently have atrial fibrillation, which imposes additional challenges due to the need for oral anticoagulation. Left atrial appendage occlusion is currently regarded as a non-inferior alternative to anticoagulation in patients with non-valvular atrial fibrillation and both high thromboembolic and bleeding risk. Considering that both MitraClip implantation and left atrial appendage occlusion are percutaneous techniques that require transseptal puncture, it is technically attractive to consider their concomitant use. OBJECTIVES: We aim to evaluate the feasibility of a combined approach with MitraClip implantation and left atrial appendage occlusion in a single procedure. METHODS: We report the first case series regarding this issue, discussing the specific advantages, pitfalls and technical aspects of combining these two procedures. RESULTS: Five patients underwent left atrial appendage occlusion with the Watchman® device followed by MitraClip implantation in the same procedure. All patients experienced significant reduction in mitral valve regurgitation of at least two grades, optimal occluder position, no associated complications and significant clinical improvement assessed by NYHA functional class (reduction of at least one functional class, with four patients in class I at one-month follow-up). CONCLUSION: In selected patients rejected for surgical mitral valve repair, with atrial fibrillation and increased risk of bleeding and embolic events, a combined approach with MitraClip implantation and left atrial appendage occlusion in a single procedure is feasible, safe and effective.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Septal Occluder Device , Aged , Cardiac Surgical Procedures/methods , Female , Humans , Male , Middle Aged , Prosthesis Implantation/methods , Referral and Consultation , Retrospective Studies
9.
Rev Port Cardiol ; 36(4): 251-256, 2017 Apr.
Article in English, Portuguese | MEDLINE | ID: mdl-28318856

ABSTRACT

INTRODUCTION: Percutaneous balloon aortic valvuloplasty (BAV) has been limited by the risk of complications and restenosis. However, growing use of transcatheter aortic valve implantation (TAVI) has revived interest in this technique. We analyzed the current indications for BAV and outcomes in a single center. METHODS: Acute results and long-term outcomes were analyzed in a retrospective single-center registry of patients undergoing BAV between January 2013 and January 2016. RESULTS: Twenty-three patients underwent BAV, 56.5% male, mean age 78±7 years. Indications were severe aortic stenosis and decompensated heart failure (n=5), urgent non-cardiac surgery (n=8), or bridge to definitive treatment (n=10). Peak invasive gradient decreased from a median of 54.0±19.0 mmHg to 28.5±13.8 mmHg (p=0.002). Complications included one ischemic stroke, one lower limb ischemia and one femoral pseudoaneurysm requiring surgery. During a mean follow-up of 11±10 months, eight patients underwent TAVI and two underwent surgical aortic valve replacement. Thirteen patients died, nine of non-cardiovascular causes. On Kaplan-Meier analysis mortality was significantly lower among patients undergoing definitive treatment (20.0% vs. 84.6% at two-year follow-up; p=0.005). CONCLUSION: BAV should be considered for selected patients with temporary contraindications to definitive therapy or as palliative therapy.


Subject(s)
Angioplasty, Balloon , Aortic Valve Stenosis/surgery , Heart Failure/surgery , Aged , Female , Humans , Male , Postoperative Complications/epidemiology , Registries , Retrospective Studies , Transcatheter Aortic Valve Replacement , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...